HM Wire Management
Use with 6-wire/3-circuit electrical distribution system |
|
This kit provides a panel with non-powered
wire management raceway at the panel base. It includes 2 raceway
covers and 1 base plate with dual power block risers.
See Color Chart Below |
| |
|
|
|
HM 3" Wire Management Kit
AO1 Non-Electrical
 |
|
|
|
This kit converts a panel without raceway
to one with powered wire management raceway. Dual Power Block
supplies up to four duplex receptacles per panel with three 20-amp
circuits; it is UL/CUL recognized under UL 1296 for power distribution and
UL 498 for receptacles. It includes 2 raceway covers, 1 base plate,
1 dual power block and 4 attaching screws. Shipped unassembled.
Note: Panel-to-panel fillers, Duplex Receptacles, Receptacle Covers,
Receptacle Windows and Festoons must be ordered separately. OEM
Compatible.
See Color Chart Below |
| |
|
|
|
HM 3" Wire Management Kit
AO1 Electrical
 Use with 6 wire/3 circuit electrical distribution |
| |
|
|
HM 3" Receptacle Cover Clips
AO1
 Use with 6-wire/3-circuit electrical distribution system
|
| |
|
Wire management base plate used with A01 or
OEM electrical distribution 6-wire/3circuit power.
Note:
Raceway covers, Panel-to panel fillers and Outlet cover clips and/0r power
must be ordered separately.
See Color Chart Below |
| |
|
|
|
HM 3" Raceway Base Plate
Series 1
 Use with 6-wire/3-circuit electrical distribution system
|
|
|
|
Wire management cover pairs that can be
used on OEM metal base plate; HMP330 (with receptacle openings) will work
with OEM 6 -wire/3-circuit power.
Note: Panel -to-panel
fillers, Base and receptacle Cover Clips must be ordered separately.
Cover Clips (HMP351.00) are required to cover unused electrical outlet
holes. |
| |
|
|
|
HM 3" Raceway Covers
AO1
 Use with 6-wire/3-circuit electrical distribution system
|
|
|
Supplies up to four duplex receptacles per
panel with three 20-amp circuits; it is Ul/CUL recognized under UL 1286
fir power distribution and UL 498 for receptacles. It is totally
compatible with OEM 6-wire/3-circuit power.
Note: Use
attaching screws, #10 x 2" type "A" self tapping screw with slotted hex
head, to affix dual power blocks to Series 1 Raceway Base plate. 4
required. |
| |
|
|
|
HM Dual Power Blocks
AO1
 Use with 6-wire/3-circuit electrical distribution system
|
|
|
Connects one electrical kit directly, or
through a connector, to an adjoining electrical kit or panel pass-through
cable. Festoons are UL/CUL recognizes under UL 1286 for power
distribution. OEM compatible. |
| |
| |
|
Festoons
AO1
 Use with 6-wire/3-circuit electrical distribution system
|
|
|
|
Continues power supply from one clerical
kit through non-powered panel(s) to another electrical kit or panel
pass-through cable. It is UL/CUL recognized under UL 1286 for power
distribution. It can be fully interchanged with OEM 6 wire/3-circuit
power. OEM compatible.
Note: Order to
match width of panel that electrical must pass through. |
| |
|
|
|
HM Pass Through Jumpers
AO1
 Use with 6-wire/3-circuit electrical distribution system
|
|
|
Locks into the base of a powered panel to
deliver one of three circuits. It is UL/CUL recognized under UL 498
for receptacles. They are compatible with OEM 6-wire/3-circuit
power. Note: Order individually.
Order Receptacle Cover Clips (HMP350.00) separately.
Available in Black Only. |
| |
|
|
|
HM Duplex Receptacles
AO1
 Use with 6-wire/3-circuit electrical distribution system
|
| |
|
Kit provides wire management covers at base
of connectors and end caps. Also replacement parts for raceway kits.
2-way, 3-way,2-way 180° and End Cap kits
include pins. OEM compatible.
See Series
1 colors on Chart |
| |
|
|
|
HM 3" Wire Management Connector Kits AO1
 Use with 6-wire/3-circuit electrical distribution system
|
|
|
|
HM 3" Wire Management Raceway Kits AO1
 Use with 6-wire/3-circuit electrical distribution system
|
|
|
|
|
HM 3" Raceway Covers/pair AO1
 Use with 6-wire/3-circuit electrical distribution system
|
|
|
|
|
HM 3" Raceway
Base Plates AO1
 Use with 6-wire/3-circuit electrical distribution system |
|
|
Use to add wire management and electrical
capability to panels. Kit includes one (1) raceway frame, two (2)
levelers, and two (2) race ways covers. HM520 Kits include slide mount (s). Top channel drilled for power and OEM Version 1 & 2 power.
See Series 2 colors on Chart. |
| |
|
|
|
HM 5" Wire Management Raceway Kit
AO2
 Use With System 4 Electrical Distribution System
|
| |
|
Use to replace raceway covers or HM OEM
raceway covers. Note: Sold in pairs.
For OEM type with cutouts call Customer Service for lead time.
See Series
2 colors on Chart. |
|
HM 5" Raceway Covers
AO2
 |
| |
|
|
| |
|
Heavy duty one-piece frame provides
electrical/communication raceway for AO2 panels. AO2
glides (HMP574-01 DT) are included. Please contact Customer Service
for 5" raceway parts for all structural steel frames |
| |
|
|
|
HM 5" Raceway Frame
AO2
 Use With System 4 Electrical Distribution System
|
| |
|
|
HM 5" Wire Management Connector Kits
AO2
 Use With System 4 Electrical Distribution System
|
|
Use to electrifyAO1 &AO2 wire management raceway.
System 4 is an 8-wire/4-circuit assembly with 2 power blocks which
accommodate up to 4 receptacles.
Note: System 4 electrical system is UL
recognized (UL
Standard 1286) and CSA certified (CSA standard C22.2 No. 203). |
| |
|
|
|
Electrical Distribution Assembly
(System 4)
Use with AO2 Wire Management Raceways
 |
| |
|
Used to continue power run through a
non-powered wire management raceway from a powered base assembly. |
| |
|
|
|
Panel Pass Through Jumper
Use With AO2 Wire Management Raceway
 |
|
|
|
Use for straight line applications
ONLY when running power
from one panel through a 3 or 4 way connector into another panel (example:
Powering a spine at a 3 or 4 way condition) |
| |
|
|
|
Panel Connector-Jumper

|
| |
|
Use to bring building power source to panel
electrical distribution assemblies. |
| |
|
|
|
Power In-Feed
Use with AO2 Wire Management Raceways
 |
| |
|
Transition jumper Connector brings power
from HM Series 2 4-circuit 8-wire electrical system to 4-circuit 8-wire
electrical system. HMP559.1500 for panel-to panel transition and
HMP559.1800 for panel-connector-panel transition. (for OEM Ao2 Version 1
only) |
| |
|
|
|
Transition Jumper Connector
Use with Series 2 Wire Management Raceways
 |
| |
|
Slide into face power block. Select
circuit a, b or c for general purpose use. Use circuit d for
isolated dedicated circuit.
Available in Black Only. |
| |
| |
|
Duplex Receptacle
Use with Series 2
 |
| |
|
This ceiling entry pole assembly connects
to the end of a panel run or at 3-or 4-way 90 degree connector. It
conceals voice/data communication cables from the ceiling entry point to
the base of the panel. Ceiling Cover Plate is 6" x 6" metal 2-piece
with cutout for power pole. Mount to ceiling tile to finish off top
condition. Plate is unpainted.
Standard Paint Finishes |
| |
|
|
|
HM Ceiling Entry Pole
 |
|
|
|
Click here for
Workstation Brackets
 |
Office
Workstations - Create a convenient workstation to house
printers, fax machines, scanners or phone systems on just about any
wall. Place the station at any height so users can access equipment
while sitting or standing. At home, create a bill paying or letter
writing area, anywhere there's extra wall space. The compact design
is a perfect space-saving solution for many modern homes. |
|